Alif Semiconductor /AE512F80F55D5AS_CM55_HE_View /ADC120 /ADC_INTERRUPT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as ADC_INTERRUPT

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (AVG_SAMPLE_RDY)AVG_SAMPLE_RDY 0 (ALL_SAMPLES_TAKEN)ALL_SAMPLES_TAKEN 0 (AVG_CALC_THRESH_0)AVG_CALC_THRESH_0 0 (AVG_CALC_THRESH_1)AVG_CALC_THRESH_1

Description

ADC Interrupt Status and Clear Register

Fields

AVG_SAMPLE_RDY

Status and clear for DONE0 interrupt. Read 1: Analog logic has delivered the number of samples set in the ADC_AVG_NUM register, indicating that the current ADC_SAMPLE_REG_n has been loaded. Write 1 to clear.

ALL_SAMPLES_TAKEN

Status and clear for DONE1 interrupt. Read 1: Data collection has now stopped with the final loading of a ADC_SAMPLE_REG_n register, due to either turning off ADC_START_SRC[START] for continuous operation, or ADC_CONTROL[START] one-time run has finished. Write 1 to clear.

AVG_CALC_THRESH_0

Status and clear for CMPA interrupt. Read 1: A threshold passed depending on ADC_CONTROL[INT_CTRL] register field. Write 1 to clear.

AVG_CALC_THRESH_1

Status and clear for CMPB interrupt. Read 1: A threshold passed depending on ADC_CONTROL[INT_CTRL] register field. Write 1 to clear.

Links

() ()